a. Highlighted OLED active-luminescent display, with clear and intuitive display;
b. TDLAS (Tunable semiconductor laser absorption spectrum) technology is used to measure without background gas cross interference;
c. The multiple reflection optical path design provides a longer effective optical path, thereby improving the measurement accuracy and precision;
d. Equipped with a polytetrafluoroethylene filtration device, it filters out impurities while maintaining the optical signal transmittance, and is easy to clean and replace;
e. The mirror heating function prevents the adhesion of viscous substances and keeps the mirror surface clean;
f. Automatic temperature and pressure compensation could eliminate the impact of environment temperature and pressure changes on the measurement accuracy;
g. 40 thousand pieces of historical data can be stored automatically, enabling user to read historical data freely;
h. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;
i. Flameproof design has high safety factor;
j. The structure is compact, with excellent reliability and stability, fast response speed, and is capable of real-time reflection of the measured gas concentration;
k. In explosion-proof places, the menu can be set by isolated magnetic pen, which is easy to operate on site;
l. Standard DN65 PN1.0 flange is installed by butt joint, which is quick and convenient to install.
l Test Principle: TDLAS (Tunable semiconductive laser absorption spectrum)
l Test Composition: O2, CO, NH3, CO2, CH4, C2H2, C3H8
l Test Range: 0-100%
(Note: Every set of analyzer can only test the concentration of one kind of gas, composition and test range are customizable)
l Display Method: 128×64 dot matrix OLED
l Resolution: 0.01%
l Light Path Length: 1.5m
l Linear Error: ≤1%.FS
l Zero Drift: ≤1%.FS/ year
l Range Drift: ≤1%.FS/ half year
l Response Time: T90<10s
l Maintenance Cycle:≤2 times/ year, clean optical window
l Calibration Cycle: ≤2 times/ year
l Input Port: 2 ways of 4-20mA input (temperature and pressure compensation)
l Output Port: 2 way of 4-20mA output (Oxygen concentration and transmittance, maximum load resistance<1KΩ)
1 way of programmable alarm relay output (Dry contact type, maximum load 220V/2A)
l Communication Output: RS485
l Power Supply: DC24V±10%,<20VA
l Ambient Temperature: -20°C~+60°C
l Operation Environment Temperature: Gauge: -20°C~+50°C
Probe:-20°C~+80°C
l Environment Humidity: <90%RH, non-condensing
l Sampling Mode: Diffusion
l Operation Pressure: 0.8~1.4bar, maximum pressure for probe 5bar
l Calibration Gas Path Connection: NPT 1/8 internal thread
l EX Grade: Ex dbⅡC T6 Gb
l Dust Proof Grade: Ex tb ⅢC T80℃ Db
l Certification Number:CNEx23.0412X
l Protection Level: IP66
l Sensor Service Life:>5 years (under normal conditions of use)
l Instrument Weight: Net weight 16.8Kg
l Installation: Plug-in, standardDN65 PN1.0 flange installation
It is applied in gas concentration detection and analysis in bioreactors, composting (processing), gas generation, oxygen content measurement, automatic inert sealing systems, solvent tanks, chemical/pharmaceutical reactions, methane/landfill gas oxygen monitoring, chemical, pharmaceutical, steel, environmental protection, food industries, etc.
l Test range
l Background gas composition